
ABB - Low Voltage Drives
RMBA-01-KIT
Alternate Item Number: 64606778
UPC: 662348077191
Documents & Media
Contact for Pricing
Overview
The ABB RMBA-01-KIT is a galvanically isolated RS-485 interface module designed for Modbus serial communication, specifically supporting the RTU protocol. This adapter module enables the connection of ABB Low Voltage Drives to an RS-485 Modbus-RTU network, facilitating integration with Modicon PLCs and other automation devices. It supports common read/write single and multiple register function codes, crucial for efficient data exchange and control within industrial automation systems. The Modbus protocol, a serial, asynchronous standard, does not specify the physical interface, but the RMBA-01 provides a reliable RS-485 connection. RS-485 is known for its multi-drop capabilities and noise immunity, making it suitable for industrial environments. The galvanic isolation is a key feature, protecting sensitive control equipment from ground loops and electrical noise, thereby enhancing system reliability and longevity. This module is part of ABB's strategy for universal connectivity, allowing ABB Low Voltage Drives to connect to virtually all controller brands and communication networks. This simplifies the interface for control and management of drives, leading to improved quality, productivity, flexibility, and scalability. The adapter modules, when combined with ABB's machinery drives, offer a powerful drive solution for OEMs and system integrators in industries such as food & beverage, material handling, printing, rubber & plastics, and textiles. Key benefits of network connectivity include decreased mechanical and electrical installation time, reduced downtime, and access to more data for enhanced operational insights and control. The RMBA-01-KIT is an essential component for applications requiring serial communication via Modbus RTU over an RS-485 network, offering a direct and effective solution for seamless integration and enhanced operational integrity within ABB drive systems.
- Enables connection of ABB Low Voltage Drives to RS-485 Modbus-RTU networks.
- Provides galvanically isolated RS-485 interface for enhanced system reliability.
- Supports common read/write single and multiple register function codes.
- Facilitates integration with Modicon PLCs and other automation devices.
- Designed for universal connectivity, simplifying drive control and management.

DLC400BP
The TORK DLC400BP SunSet 365-Day Astronomic Digital Timer is designed for providing total control over 4 different output channels in indoor or outdoor applications. Automate your home or office to save energy and money using the intuitive programming interface and light sensitive activation to activate lights or signage when the ambient light level drops below a customizable threshold. Features four output channel, different settings for holidays and seasons and a 6-month battery backup. Designed for commercial applications including lighting, HVAC equipment, signage, store windows and security or parking lot lights.
FSO-12-KIT
The FSO 12 safety functions module supports the following functions according to EN/IEC 61800-5-2:2007: Safe Torque Off (STO) (standard feature of the drive), Safe Brake Control (SBC), Safe Stop 1 (SS1), and, Safely-Limited Speed (SLS). Additional safety functions supported but not specified in EN/IEC 61800-5-2:2007: Safe Stop Emergency (SSE), Safe Maximum Speed (SMS), and, Prevention of Unexpected Start-up (POUS). The FSO 12 does not operate the drive, it only monitors the actions of the drive and commands safety functions to be executed. The request for safety functions can come from an external safety system, safety PLC or from an FSO 12 internal fault. The FSO module monitors that the drive operates within the configured limits, and if the limits are exceeded, activates the STO function in the drive within the response time. Activation of the drive STO function removes the torque and, if so configured, applies the brake. Commissioning and configuration of the safety functions requires Drive composer pro (DCPT-01-KIT). NOTE: The Safe Torque Off (STO) function does not disconnect the voltage of the main and auxiliary circuits from the drive. NOTE: This module does not support an encoder in safety applications.
2TLA020070R4700
Safety PLC. Totally 20 I/O: 8 failsafe inputs + 8 non-failsafe outputs/failsafe inputs + 2 individually failsafe relay outputs + 2 individually failsafe transistor outputs. (Without Pluto safety bus). NOTE: Version 2 hardware/processor.
PAC79
Aluminum Type PAC - Aluminum Parallel Groove Clamp with Cast Copper Liner for Wire Range Main: 336.4-1/0, 1/0-6 AR ASCR 400-2/0 Str., 1/0-6 AR AL/CU, Tap: ASCR 1/0 Str.-8 Sol. ALCU, Prefilled with Oxide Inhibitor.



