ABB Low Voltage Drives DCS800-S02-0520-05+L508 MODULE DRIVE 4-QUADRANT (REVERSING), Product Family: DCS800, Horsepower: 125 HP @ 230…
Alternate Item Number: 3AUA0000061812
UPC: 662348074817
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 4-quadrant operation for bidirectional motor control and regenerative braking
- 125 HP @ 230 VAC / 300 HP @ 460 VAC with 485 A @ 240 VDC / 489 A @ 500 VDC output
- DDCS communications board for industrial automation integration
- Wall-mountable design (18.1" x 10.6" x 12.2") weighing 55 lbs
- Compatible with 3-phase input systems (230/240 V and 460/500 V)
Specifications
Package Dimensions (L x W x H) | 21 in x 15 in x 15 in |
Package Dimensions (L x W x H) | 53.34 cm x 38.1 cm x 38.1 cm |
Package Weight (Imperial) | 62.000 L |
Package Weight (Metric) | 28.123 kg |

DCS800-EP1-0610-05+S235
PANEL DRIVE 2-QUADRANT (NON-REVERSING), Product Family: DCS800, Horsepower: 150 HP, Output Current: 506 A, Voltage: 230 VAC /240 VDC, UL TYPE OPEN (IP00), Mounting: Cabinet-mount, 3-Phase Input, Frame: C-D4, Product HxWxD: 35.32 in x 23.58 in x 16.17 in, Product Weight: 260 lbs
DCS800-S02-0025-05+K454+L508
MODULE DRIVE 4-QUADRANT (REVERSING), Product Family: DCS800, Horsepower: 5 HP @ 230 VAC / 10 HP @ 460 VAC, Output Current: 23 A @ 240 VDC / 23 A @ 500 VDC, Voltage: 230 VAC/240 VDC & 460 VAC/500 VDC, UL TYPE OPEN (IP00), Mounting: Wall-mount, ProfiBus-DP Adapter, DDCS Communications Board, 3-Phase Input, Frame: D1, Product HxWxD: 14.6 in x 10.6 in x 7.9 in, Product Weight: 24 lbs
DCS800-S02-0820-05+K454+L502+S171
MODULE DRIVE 4-QUADRANT (REVERSING), Product Family: DCS800, Horsepower: 200 HP @ 230 VAC / 500 HP @ 460 VAC, Output Current: 780 A @ 240 VDC / 806 A @ 500 VDC, Voltage: 230 VAC/240 VDC & 460 VAC/500 VDC, UL TYPE OPEN (IP00), Mounting: Wall-mount, ProfiBus-DP Adapter, Pulse Encoder Interface, 120 VAC Fan Voltage, 3-Phase Input, Frame: D4, Product HxWxD: 25.4 in x 10.6 in x 13.6 in, Product Weight: 84 lbs
DCS800-S02-0200-05+S186
MODULE DRIVE 4-QUADRANT (REVERSING), Product Family: DCS800, Horsepower: 50 HP @ 230 VAC / 100 HP @ 460 VAC, Output Current: 190 A @ 240 VDC / 190 A @ 500 VDC, Voltage: 230 VAC/240 VDC & 460 VAC/500 VDC, UL TYPE OPEN (IP00), Wall-mounted, Low Mains Voltage Adapter Board, 3-Phase Input, Frame: D2, Product HxWxD: 14.6 in x 10.6 in x 10.6 in, Product Weight: 35 lbs
DCS800-S02-0520-05+K462+S199
MODULE DRIVE 4-QUADRANT (REVERSING), Product Family: DCS800, Horsepower: 125 HP @ 230 VAC / 300 HP @ 460 VAC, Output Current: 485 A @ 240 VDC / 489 A @ 500 VDC, Voltage: 230 VAC/240 VDC & 460 VAC/500 VDC, UL TYPE OPEN (IP00), Mounting: Wall-mount, ControlNet Adapter, Drive-to-drive Communication Board, 3-Phase Input, Frame: D3, Product HxWxD: 18.1 in x 10.6 in x 12.2 in, Product Weight: 55 lbs
DCS800-S01-0405-05+S199
MODULE DRIVE 2-QUADRANT (NON-REVERSING), Product Family: DCS800, Horsepower: 100 HP @ 230 VAC / 100 HP @ 460 VAC, Output Current: 385 A @ 240 VDC / 385 A @ 500 VDC, Voltage: 230 VAC/240 VDC & 460 VAC/500 VDC, UL TYPE OPEN (IP00), Mounting: Wall-mount, Drive-to-drive Communication Board, 3-Phase Input, Frame: D3, Product HxWxD: 18.1 in x 10.6 in x 12.2 in, Product Weight: 55 lbs
DCS800-S02-0100-05+S202
MODULE DRIVE 4-QUADRANT (REVERSING), Product Family: DCS800, Horsepower: 25 HP @ 230 VAC / 50 HP @ 460 VAC, Output Current: 95 A @ 240 VDC / 95 A @ 500 VDC, Voltage: 230 VAC/240 VDC & 460 VAC/500 VDC, UL TYPE OPEN (IP00), Mounting: Wall-mount, 3-Phase Input, Frame: D1, Product HxWxD: 14.6 in x 10.6 in x 7.9 in, Product Weight: 24 lbsFrequently Asked Questions
What is the enclosure rating of the DCS800-S0x power converter module?
The DCS800-S0x power converter module has a NEMA TYPE OPEN (IP00) rating and requires mounting in a protective enclosure.
What is the voltage range for system connection?
The system connection voltage is 3-phase, 240 to 990 V per IEC 60038, with a continuous deviation of ±10% and up to 0.5 sec. of ±15%.
What is the rated frequency for the drive?
The rated frequency is 50 Hz or 60 Hz, with static frequency deviation of ±2% and dynamic frequency range of ±5 Hz.
What are the Short Circuit Current Ratings (SCCR) for different frame sizes?
Frame sizes D1 - D4 have an SCCR of 65 kA, while D5 - D7 have an SCCR of 100 kA.
What is the permissible cooling air temperature for the converter module?
The permissible cooling air temperature at the converter module air inlet is 0 to +55°C, but derating is required above +40°C with rated DC current.
What are the humidity limits for the drive?
Relative humidity is 5 to 95% (no condensation) at 5 to 40°C, and 5 to 50% (no condensation) at 0 to 5°C.
What is the storage and transport temperature range?
The storage temperature range is -40 to +55°C, and the transport temperature range is -40 to +70°C.
What are the overload capabilities for Normal, Standard, and Heavy Duty?
Normal Duty allows 110% overload for 60 seconds, Standard Duty allows 150% for 30 seconds, and Heavy Duty allows 150% for 60 seconds.
When should I use a non-reversing (2-Q) drive?
Use a 2-Q drive when motor torque and speed are in the same direction and significant stopping power is not needed, like for fans or pumps.
What are the limitations of a 2-Q drive?
A 2-Q drive cannot slow down an inertial load or reverse direction unless field reversal is used.