Authorized ABB Distributor (Low Voltage Drives)
ABB - Low Voltage Drives ACS800-U31-0100-5+E200+K466+L502 - WALL-MOUNTED DRIVE ULTRA LOW HARMONIC , Product Family: ACS800, Horsepower: 100 HP, Output Current: 132 A, Voltage: 480 VAC, Voltage Range: 380-500V, NEMA 1 / UL Type 1 (IP21), Wall-mounted, Local or Remote Mounted LCD Display and Keypad, EtherNet Adapter, Pulse Encoder Interface, EMC/RFI Filter (2nd Envir), 3-Phase Input, 3-Phase Output, Frame: R6, Product HxWxD: 38.19 in x 11.81 in x 17.28 in, Product Weight: 221 lbs

ABB Low Voltage Drives ACS800-U31-0100-5+E200+K466+L502 WALL-MOUNTED DRIVE ULTRA LOW HARMONIC , Product Family: ACS800, Horsepower: 100 HP…

Alternate Item Number: 3AUA0000059385

UPC: 662348057964


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB ACS800-U31-0100-5+E200+K466+L502 is a high-performance, wall-mounted drive designed for industrial applications requiring ultra-low harmonic distortion. With a power rating of 100 HP and an output current of 132A, this drive operates at 480VAC with a voltage range of 380-500V, ensuring compatibility with a wide range of industrial systems. Featuring a NEMA 1 / UL Type 1 (IP21) enclosure, this drive is built for durability and reliability in demanding environments. The unit includes a local or remote-mounted LCD display and keypad for easy operation, along with an EtherNet adapter and pulse encoder interface for advanced connectivity. Equipped with an EMC/RFI filter for enhanced electromagnetic compatibility, this drive ensures smooth and efficient operation. The 3-phase input and output make it suitable for a variety of industrial machinery, while its compact yet robust design (38.19" x 11.81" x 17.28") and 221 lbs weight make it easy to integrate into existing systems. Ideal for applications requiring precise control and energy efficiency, the ABB ACS800 drive delivers superior performance and reliability.
  • 100 HP power rating with 132A output current for high-performance industrial applications
  • Ultra-low harmonic distortion for improved power quality and efficiency
  • 480VAC operation with a voltage range of 380-500V for versatile compatibility
  • NEMA 1 / UL Type 1 (IP21) enclosure for durability in harsh environments
  • Local or remote-mounted LCD display and keypad for easy operation and monitoring

Specifications

Package Dimensions (L x W x H)
45 IN x 16 IN x 23 IN
Package Dimensions (L x W x H)
114.3 cm x 40.64 cm x 58.42 cm
600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz

CRX0011AC

600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.

FENA-21

The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.
KDR, 208V, 19A, 5HP

KDRB22L

KDR, 208V, 19A, 5HP

Frequently Asked Questions

What is the operating temperature range for the ACS800-U31 drive?

The drive operates from -15 to +50°C, with reduced output current above 40°C. No frost is allowed.

What protection class does the standard ACS800-U31 enclosure have?

The standard enclosure for the ACS800-U31 has a UL Type 1 protection class.

Does the ACS800-U31 require external filtering for low harmonics?

No, the ACS800-U31 has a built-in LCL line filter that eliminates the need for external filtering equipment.

What is the power factor of the ACS800-U31 drive?

The ACS800-U31 operates with a unity power factor of 1 for the fundamental and a total power factor of 0.99.

What is the Short Circuit Current Rating (SCCR) for the ACS800-U31?

The SCCR for the ACS800-U31 is 65kA.

What is the efficiency of the ACS800-U31 at nominal power?

The efficiency of the ACS800-U31 at nominal power is 97%.

What is the standard cooling method for the ACS800-U31?

The standard cooling method is dry clean air.

What is the maximum relative humidity for operation?

The maximum relative humidity for operation is 95%, with no condensation allowed.

Does the ACS800-U31 meet harmonic standards?

Yes, it meets the strictest standards, including IEEE519 at the drive input terminals, even on the weakest AC line network.

What is the motor control technology used in the ACS800-U31?

The ACS800-U31 uses ABB’s exclusive Direct Torque Control (DTC) for motor control.