Overview
- 30 HP (0030 KVA) output with 83 A current at 240 VAC (208-240V range)
- NEMA 1 / UL Type 1 (IP21) enclosure for standard industrial environments
- Wall-mounted design with compact dimensions: 32.12" x 10.43" x 15.35" and 144 lbs weight
- 3-phase input and output for seamless integration into industrial systems
- Local or remote-mounted LCD display and keypad for intuitive control and monitoring
Specifications
Current Rating | 83 A |
IP Rating | IP21 |
Mounting Type | Wall |
Nema Rating | NEMA 1 |
Series | ACS800 |
Size | 32.12 x 10.43 x 15.35 in |
Voltage Rating | 208-240 VAC |
Package Dimensions (L x W x H) | 45 IN x 16 IN x 23 IN |
Package Dimensions (L x W x H) | 114.3 cm x 40.64 cm x 58.42 cm |

FENA-21
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.Frequently Asked Questions
What is the operating temperature range for the ACS800-U31 drive?
The drive can operate between -15 to +50°C, with reduced output current above 40°C. For ACS800-07LC, it's 0 to +55°C, with reduced output above 45°C.
What protection class does the standard ACS800-U31 offer?
The standard ACS800-U31 drive has a UL Type 1 protection class.
What is the power factor of the ACS800-U31 drive?
The ACS800-U31 drive operates with a unity power factor (cosϕ1 = 1) and a total power factor of 0.99.
What is the efficiency of the ACS800-U31 drive at nominal power?
The efficiency of the ACS800-U31 drive at nominal power is 97%.
What supply voltage options are available for the ACS800-U31 drive?
The drive supports 3-phase supply voltages of 208-240 V, 380-500 V, and 525-690 V.
How does the ACS800-U31 address harmonic distortion?
It uses an active converter controlled with DTC for low-order harmonics and an LCL filter for high-order harmonics, meeting IEEE519 standards.
What is the Short Circuit Current Rating (SCCR) for the ACS800-U31?
The ACS800-U31 has a Short Circuit Current Rating (SCCR) of 65ka.
What is the maximum humidity for operation?
The drive can operate in relative humidity of 5 to 95%, with no condensation allowed.
Does the ACS800-U31 require external filtering for low harmonics?
No, the ACS800-U31 has a built-in low harmonic LCL filter, eliminating the need for external filtering equipment.
What is the cooling method for the ACS800-U31?
The drive is cooled by dry, clean air.