Authorized ABB Distributor (Low Voltage Drives)
ABB - Low Voltage Drives ACS800-U31-0030-2 - WALL-MOUNTED DRIVE ULTRA LOW HARMONIC , Product Family: ACS800, Horsepower: 30 HP, Output Current: 83 A, Voltage: 240 VAC, Voltage Range: 208-240V, NEMA 1 / UL Type 1 (IP21), Wall-mounted, Local or Remote Mounted LCD Display and Keypad, 0030 KVA, 3-Phase Input, 3-Phase Output, Frame: R5, Product HxWxD: 32.12 in x 10.43 in x 15.35 in, Product Weight: 144 lbs

ABB Low Voltage Drives ACS800-U31-0030-2 WALL-MOUNTED DRIVE ULTRA LOW HARMONIC , Product Family: ACS800, Horsepower: 30 HP…

Alternate Item Number: 3AUA0000011962

UPC: 662348057384


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB ACS800-U31-0030-2 is a wall-mounted, ultra-low harmonic AC drive engineered for industrial applications requiring precise motor control and energy efficiency. Part of ABB’s ACS800 series, this drive delivers 30 HP (0030 KVA) with a 3-phase output current of 83 A at 240 VAC (208-240V range). The NEMA 1 / UL Type 1 (IP21) enclosure ensures reliable operation in standard industrial environments, protecting against dust and non-corrosive contaminants. Designed for space-constrained installations, the ACS800-U31-0030-2 features a compact footprint measuring 32.12" (H) x 10.43" (W) x 15.35" (D) and weighs 144 lbs, making it ideal for wall-mounted applications. The drive supports both local and remote-mounted LCD display and keypad for intuitive control and monitoring, with a 3-phase input and output configuration for seamless integration into existing systems. Key applications include pumps, fans, conveyors, and compressors where ultra-low harmonic distortion is critical to meet power quality standards. The ACS800 series is known for its reliability, advanced features, and compatibility with industrial automation systems, ensuring minimal downtime and extended equipment life. With ABB’s reputation for quality, this drive provides a dependable solution for facilities seeking to optimize energy consumption and motor performance.
  • 30 HP (0030 KVA) output with 83 A current at 240 VAC (208-240V range)
  • NEMA 1 / UL Type 1 (IP21) enclosure for standard industrial environments
  • Wall-mounted design with compact dimensions: 32.12" x 10.43" x 15.35" and 144 lbs weight
  • 3-phase input and output for seamless integration into industrial systems
  • Local or remote-mounted LCD display and keypad for intuitive control and monitoring

Specifications

Current Rating
83 A
IP Rating
IP21
Mounting Type
Wall
Nema Rating
NEMA 1
Series
ACS800
Size
32.12 x 10.43 x 15.35 in
Voltage Rating
208-240 VAC
Package Dimensions (L x W x H)
45 IN x 16 IN x 23 IN
Package Dimensions (L x W x H)
114.3 cm x 40.64 cm x 58.42 cm
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.

FENA-21

The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.
600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz

CRX0011AC

600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz
KDR, 208V, 19A, 5HP

KDRB22L

KDR, 208V, 19A, 5HP

Frequently Asked Questions

What is the operating temperature range for the ACS800-U31 drive?

The drive can operate between -15 to +50°C, with reduced output current above 40°C. For ACS800-07LC, it's 0 to +55°C, with reduced output above 45°C.

What protection class does the standard ACS800-U31 offer?

The standard ACS800-U31 drive has a UL Type 1 protection class.

What is the power factor of the ACS800-U31 drive?

The ACS800-U31 drive operates with a unity power factor (cosϕ1 = 1) and a total power factor of 0.99.

What is the efficiency of the ACS800-U31 drive at nominal power?

The efficiency of the ACS800-U31 drive at nominal power is 97%.

What supply voltage options are available for the ACS800-U31 drive?

The drive supports 3-phase supply voltages of 208-240 V, 380-500 V, and 525-690 V.

How does the ACS800-U31 address harmonic distortion?

It uses an active converter controlled with DTC for low-order harmonics and an LCL filter for high-order harmonics, meeting IEEE519 standards.

What is the Short Circuit Current Rating (SCCR) for the ACS800-U31?

The ACS800-U31 has a Short Circuit Current Rating (SCCR) of 65ka.

What is the maximum humidity for operation?

The drive can operate in relative humidity of 5 to 95%, with no condensation allowed.

Does the ACS800-U31 require external filtering for low harmonics?

No, the ACS800-U31 has a built-in low harmonic LCL filter, eliminating the need for external filtering equipment.

What is the cooling method for the ACS800-U31?

The drive is cooled by dry, clean air.