ABB Low Voltage Drives ACS550-U1-07A5-2+B055 ACS550 AC Drive, 3-200-240V In, 2HP, 7.5A, Type 12/IP55, 1.1 overload, Advanced, 18.1 x…
Alternate Item Number: 3AUA0000004193
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 2HP output power at 7.5A rated current for 3-phase 200-240V AC input
- IP55 enclosure with Type 12 rating for dust and water resistance
- 1.1 overload capacity (8.25A peak) for handling transient loads
- Compact wall-mount design (18.1 x 8.4 x 9.2 in) for space-efficient installation
- Advanced control modes: sensorless vector and V/f for energy efficiency
Specifications
Control Panel | Advanced |
Frame Size | R1 |
Input Phase | 3-Phase |
IP Rating | IP55 |
Output Current | 7.5 |
Output Phase | 3-Phase |
UL Type | 12 |
Voltage | 240 |
Voltage Range | 208-240 |
Package Dimensions (L x W x H) | 9.2 in x 8.4 in x 18.1 in |
Package Dimensions (L x W x H) | 23.368 cm x 21.336 cm x 45.974 cm |
Package Weight (Imperial) | 17.600 L |
Package Weight (Metric) | 7.983 kg |

FENA-21
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.Frequently Asked Questions
What is the input voltage range for ACS550 drives?
The drives support 3-phase input voltages of 208 to 240 V, 380 to 480 V, and 500 to 600 V, with a tolerance of +10/-15%.
What are the product compliance and certifications for the drives?
The drives have UL, cUL, CSA, CE, C-TICK, and GOST-R approvals, and are seismic certified to ICC AC-156 criteria.
What is the operating frequency range for the motor connection?
The motor connection frequency range is from 0 to 500 Hz.
What serial communication protocol is built-in?
The drive has a built-in RS 485 serial communication with Modbus RTU protocol.
What is the recommended ambient temperature range for operation?
The ambient temperature range for operation is 15 to 40°C (5 to 104°F).
What are the acceleration and deceleration time limits?
Acceleration and deceleration times can be set between 0.1 to 1800 seconds.
What is the maximum allowable relative humidity?
The relative humidity should be lower than 95%, without condensation.
What types of analog inputs are available?
There are two analog inputs that accept voltage signals (0-10V) or current signals (0-20mA).
What is the auxiliary voltage output?
The auxiliary voltage output is 24 V DC with a maximum current of 250 mA.
How many digital inputs does the drive have?
The drive is equipped with six digital inputs that can be used with internal or external supply.