ABB Low Voltage Drives ACS550-PD-012A-4+B055 GENERAL PURPOSE PACKAGED DRIVE W/ DISCONNECT SWITCH AND FUSES, Product Family: ACS550…
Alternate Item Number: 3AUA0000030543
UPC: 662348043769
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 7.5 HP Motor Rating
- 480 VAC, 3-Phase Input/Output
- NEMA 12 / UL Type 12 (IP54) Enclosure
- Includes Disconnect Switch and Fuses
- Wall-Mounted Design with Advanced Control Panel
Specifications
Package Dimensions (L x W x H) | 51 IN x 12 IN x 18 IN |
Package Dimensions (L x W x H) | 129.54 cm x 30.48 cm x 45.72 cm |

FENA-21
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.Frequently Asked Questions
What are the input voltage and frequency ranges for ACS550 drives?
The drives support 3-phase input voltages of 208-240V, 380-480V, and 500-600V, with a frequency range of 48 to 63 Hz.
What is the output frequency range for motor connection?
The motor connection supports an output frequency range from 0 to 500 Hz.
What is the power factor of the ACS550 drives?
The power factor for the ACS550 drives is 0.98.
What are the acceleration and deceleration time ranges?
Acceleration and deceleration times can be set between 0.1 to 1800 seconds.
What types of analog inputs are available?
There are two analog inputs that accept voltage signals (0-10V) or current signals (0-20mA).
What is the accuracy of the analog outputs?
The analog outputs provide a 0-20mA signal with an accuracy of ±3%.
What is the auxiliary voltage provided by the drive?
The drive provides an auxiliary voltage of 24V DC ±10% with a maximum current of 250 mA.
How many digital inputs does the drive have and what are their specifications?
There are six digital inputs that accept 12V to 24V DC with a maximum delay of 5 ms.
What are the specifications for the relay outputs?
The three relay outputs can switch a maximum voltage of 250V AC/30V DC and a maximum current of 6A.
What serial communication protocol is built-in?
The drive has a built-in RS 485 serial communication with Modbus RTU protocol.