Authorized ABB Distributor (Low Voltage Drives)
ABB - Low Voltage Drives ABB-44496 - Braking Resistor, 8.06 OHMS, 5592 WATTS, GCE9 Enclosure, 26.5W x 10D x 5H in, 24 lbs

ABB Low Voltage Drives ABB-44496 Braking Resistor, 8.06 OHMS, 5592 WATTS, GCE9 Enclosure, 26.5W x 10D x 5H in, 24 lbs

Alternate Item Number: 3AUA0000015231

UPC: 662348000649


Documents & Media
Technical DrawingSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Braking Resistor (SKU: ABB-44496) is engineered for effective energy dissipation in industrial motor drive applications. This unit features a resistance of 8.06 OHMS and a substantial power rating of 5592 WATTS, ensuring it can handle significant braking energy. It is housed within a GCE9 enclosure, providing robust protection for the internal components in demanding industrial settings. The physical dimensions are 26.5 inches wide, 10 inches deep, and 5 inches high, with a weight of 24 lbs, facilitating straightforward integration into existing control panels and machinery. Manufactured by ABB - Low Voltage Drives, this braking resistor is designed for reliable operation in systems such as conveyors, elevators, and other machinery requiring controlled deceleration. Its specifications make it suitable for applications where heat dissipation is critical for system longevity and performance. The UNSPSC code is 39122004, and it is manufactured in the US.
  • Resistance: 8.06 OHMS
  • Power Rating: 5592 WATTS
  • Enclosure Type: GCE9
  • Dimensions: 26.5"W x 10"D x 5"H
  • Weight: 24 lbs
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
HMI door mounting kit with 2M cable

181B0399

HMI door mounting kit with 2M cable
CONDUIT MODULE B(LSLV-S100),DFR2-S100

64150005

CONDUIT MODULE B(LSLV-S100),DFR2-S100
FAN POWER SUPPLY BOARD CFV1D.400V/48V

CFW11SP-12387920

FAN POWER SUPPLY BOARD CFV1D.400V/48V
Braking Resistor, 6.1 OHMS, 9444 WATTS, GCE18 Enclosure, 28W x 10D x 10H in, 47 lbs

ABB-44499

Braking Resistor, 6.1 OHMS, 9444 WATTS, GCE18 Enclosure, 28W x 10D x 10H in, 47 lbs
TTL incremental Pulse Encoder Interface module. The module is capable of operating at 24VDC signal with a max frequency of 200kHz. This option uses 55 mA of the available 250 mA power supply.

RTAC-03-KIT

TTL incremental Pulse Encoder Interface module. The module is capable of operating at 24VDC signal with a max frequency of 200kHz. This option uses 55 mA of the available 250 mA power supply.
Panel mounting platform for CDP312R is NEMA 12 rated and includes the 3 meter cable. The CDP-312R panel must be purchased separately. Maximum door panel thickness 14ga (2.5mm).

RPMP-11

Panel mounting platform for CDP312R is NEMA 12 rated and includes the 3 meter cable. The CDP-312R panel must be purchased separately. Maximum door panel thickness 14ga (2.5mm).
The Resolver Interface module offers interface for an analog resolver connection. A resolver may be used to obtain accurate speed and position (angle) feedback from a motor shaft. Application software supporting the Resolver interface, Positioning Control, Permanent Magnet Synchronous Machine. Limited Application SW Support, Check with factory

RRIA-01-KIT

The Resolver Interface module offers interface for an analog resolver connection. A resolver may be used to obtain accurate speed and position (angle) feedback from a motor shaft. Application software supporting the Resolver interface, Positioning Control, Permanent Magnet Synchronous Machine. Limited Application SW Support, Check with factory

Frequently Asked Questions

What is the purpose of a braking resistor with variable frequency drives?

Braking resistors increase braking torque capability and dissipate regenerated power to prevent bus voltage from exceeding the drive's rated limit.

What is the role of a braking chopper (module)?

Braking modules monitor the drive's DC bus and activate external braking resistors to manage regenerated power and avoid over-voltage trips.

What is the function of the thermal switch in Type GCE and ED enclosures?

The normally closed thermal switch detects resistor temperature overloads and is used for protection.

What is the purpose of the resistor element being thermally bound to the case?

This allows the element heat to transfer to the metallic case, enabling efficient cooling of the resistor.

How are Powerohm Type CR resistors constructed?

They feature a nickel-chromium wire wound inside a ceramic fixture, placed in a corrosion-resistant aluminum case with high-temperature wire leads.

When should 200ºC rated wire be used with Type ED enclosures?

Use 200ºC rated silicone or Teflon wire when attaching directly to resistor coils if installing without optional terminal connections.

What is the standard Brake Module supply for ACS550-U1- drives?

The Brake Module is supplied as standard up to 10 Hp and is optional for drives above 10 Hp.

What is the standard Brake Module supply for ACS550-U1- (380-480V) drives?

The Brake Module is supplied as standard up to 15 Hp and is optional for drives above 15 Hp.

What wire rating is required for Type GCE enclosure conduit knockouts?

Standard 90ºC rated wire is used when routed into the compartment through the removable 1/2 inch conduit knockouts.

What are the voltage and duty cycle specifications for ACS150/355-01U- drives?